PS-LCC-57V-2000 PS-LCC-57V-2000
PowerShift® 7,695 Watt Constant Voltage DC-DC Converter
PS-LCC-57V-2000
  • Product Brand: PowerShift®
  • Product Type: DC/DC Converter
  • Input Current Range: 0-219 A @ -38Vdc
  • Input Voltage Range: -38 to -57 Vdc
  • Output Current Range: 0–45 A
PS-LCC-57V-2000
  • Product Brand: PowerShift®
  • Product Type: DC/DC Converter
  • Input Current Range: 0-219 A @ -38Vdc
  • Input Voltage Range: -38 to -57 Vdc
  • Output Current Range: 0–45 A
460200126 460200126
PowerShift® Metro AC/DC Module, 48VDC SIERRA 25 CONVERTER
460200126
  • Product Brand: PowerShift Metro®
  • Product Type: Module
  • Input Voltage Range: -32 to -63 Vdc
  • Output Voltage Range: -32 to -63 Vdc
460200126
  • Product Brand: PowerShift Metro®
  • Product Type: Module
  • Input Voltage Range: -32 to -63 Vdc
  • Output Voltage Range: -32 to -63 Vdc
460200127 460200127
PowerShift® Metro DC/DC Module, 380V IRIS 25 CONVERTER
460200127
  • Product Brand: PowerShift Metro®
  • Product Type: Module
460200127
  • Product Brand: PowerShift Metro®
  • Product Type: Module
DPCPWR-NODE-1000 DPCPWR-NODE-1000
PowerShift Metro® 1000W Remote Node, 380V to 48V converter, Small Cell Pole-Mounted
DPCPWR-NODE-1000
  • Product Brand: PowerShift Metro®
  • Product Type: Module
  • Input Voltage Range: ±190 Vdc (± 125 Vdc to ± 200 Vdc)
  • Output Current Range: 0–22 A
  • Output Voltage Range: -52 to -56 Vdc
DPCPWR-NODE-1000
  • Product Brand: PowerShift Metro®
  • Product Type: Module
  • Input Voltage Range: ±190 Vdc (± 125 Vdc to ± 200 Vdc)
  • Output Current Range: 0–22 A
  • Output Voltage Range: -52 to -56 Vdc
DPCPWR-NODE-1500 DPCPWR-NODE-1500
PowerShift Metro® 1500W Remote Node, 380V to 48V converter, Small Cell Pole-Mounted
DPCPWR-NODE-1500
  • Product Brand: PowerShift Metro®
  • Product Type: Module
  • Input Voltage Range: ±190 Vdc (± 125 Vdc to ± 200 Vdc)
  • Output Current Range: 0-33.3 A
  • Output Voltage Range: -46 to -57 Vdc
DPCPWR-NODE-1500
  • Product Brand: PowerShift Metro®
  • Product Type: Module
  • Input Voltage Range: ±190 Vdc (± 125 Vdc to ± 200 Vdc)
  • Output Current Range: 0-33.3 A
  • Output Voltage Range: -46 to -57 Vdc
PS-1-73 PS-1-73
PowerShift® Module, 3 separate 1460 watts circuits per module, 4380 watts total per module, Patent Pending
PS-1-73
  • Product Brand: PowerShift®
  • Product Series: V1
  • Product Type: Module
  • Input Current Range: 0–36 A
  • Input Voltage Range: -42 to -59.5 Vdc
  • Output Current Range: 0–20 A
  • Output Voltage Range: -48 to -73 Vdc
PS-1-73
  • Product Brand: PowerShift®
  • Product Series: V1
  • Product Type: Module
  • Input Current Range: 0–36 A
  • Input Voltage Range: -42 to -59.5 Vdc
  • Output Current Range: 0–20 A
  • Output Voltage Range: -48 to -73 Vdc
PS-1-73-EURO PS-1-73-EURO
PowerShift® Module, 3 separate 1460 watts circuits per module, 4380 watts total per module, Patent Pending
PS-1-73-EURO
  • Product Brand: PowerShift®
  • Product Series: V1
  • Product Type: Module
  • Input Current Range: 0–36 A
  • Input Voltage Range: -42 to -59.5 Vdc
  • Output Current Range: 0–20 A
  • Output Voltage Range: -48 to -73 Vdc
PS-1-73-EURO
  • Product Brand: PowerShift®
  • Product Series: V1
  • Product Type: Module
  • Input Current Range: 0–36 A
  • Input Voltage Range: -42 to -59.5 Vdc
  • Output Current Range: 0–20 A
  • Output Voltage Range: -48 to -73 Vdc
PS-1600-73 PS-1600-73
PowerShift® Module, 2 separate 2000 watts circuits per module
PS-1600-73
  • Product Brand: PowerShift Macro®
  • Product Series: V2
  • Product Type: Module
  • Input Current Range: 0-57 A @ -38Vdc
  • Input Voltage Range: -38 to -58 Vdc
  • Output Current Range: 0-30 A
  • Output Voltage Range: -48 to -73 Vdc
PS-1600-73
  • Product Brand: PowerShift Macro®
  • Product Series: V2
  • Product Type: Module
  • Input Current Range: 0-57 A @ -38Vdc
  • Input Voltage Range: -38 to -58 Vdc
  • Output Current Range: 0-30 A
  • Output Voltage Range: -48 to -73 Vdc
PS-1900-73 PS-1900-73
PowerShift® Module, 2 separate 2430 watts circuits per module
PS-1900-73
  • Product Brand: PowerShift Macro®
  • Product Series: V2 | V3
  • Product Type: Module
  • Input Current Range: 0-57 A @ -38Vdc
  • Input Voltage Range: -38 to -58 Vdc
  • Output Current Range: 0–33 A
  • Output Voltage Range: -48 to -73 Vdc
PS-1900-73
  • Product Brand: PowerShift Macro®
  • Product Series: V2 | V3
  • Product Type: Module
  • Input Current Range: 0-57 A @ -38Vdc
  • Input Voltage Range: -38 to -58 Vdc
  • Output Current Range: 0–33 A
  • Output Voltage Range: -48 to -73 Vdc
PS-BYPASS-1 PS-BYPASS-1
PowerShift® Module, 2 circuit Bypass module, Patent Pending
PS-BYPASS-1
  • Product Brand: PowerShift®
  • Product Series: V2
  • Product Type: Module
  • Input Voltage Range: -38 to -58 Vdc
  • Output Current Range: < 40 A
  • Output Voltage Range: -38 to 58 Vdc
PS-BYPASS-1
  • Product Brand: PowerShift®
  • Product Series: V2
  • Product Type: Module
  • Input Voltage Range: -38 to -58 Vdc
  • Output Current Range: < 40 A
  • Output Voltage Range: -38 to 58 Vdc
PS-CONV-48-24 PS-CONV-48-24
PowerShift Power Supply, 48/24V DC 20A Converter panel, 19/23 in, 1 RU high, with four 24V DC GMT fuse outputs
PS-CONV-48-24
  • Portfolio: CommScope®
  • Product Brand: PowerShift®
  • Product Type: DC/DC Converter
  • Rack Type: EIA 19 in
  • Rack Units: 1
PS-CONV-48-24
  • Portfolio: CommScope®
  • Product Brand: PowerShift®
  • Product Type: DC/DC Converter
  • Rack Type: EIA 19 in
  • Rack Units: 1
PS-R-1 PS-R-1
PowerShift® Rack, accommodates up to 4 modules (3 separate circuits each for a total capacity of 12 RRU's when all 4 modules are installed)
PS-R-1
  • Product Brand: PowerShift®
  • Product Series: V1
  • Product Type: Shelf
  • Rack Type: EIA 19 in
  • Rack Units: 1
PS-R-1
  • Product Brand: PowerShift®
  • Product Series: V1
  • Product Type: Shelf
  • Rack Type: EIA 19 in
  • Rack Units: 1
oMHeZA3A4GUcB8ZuPdzfBB
Video

PowerShift: la primera fuente de alimentación de CC plug-and-play inteligente del sector

Ver
nTw7djAfZyQFrddJ3SVSaA
Video

PowerShift Metro: solución integral de extremo a extremo para alimentación distribuida, fibra y respaldo de batería para su red de pequeñas células en exteriores.

Ver

Clasificar por:

Filtros

  • Brochure: CommScope solutions para el programa de quitar y reemplazar componentes de EE. UU.

    Los encargados de hacer el equipo de red son importantes en lo que respecta a la seguridad nacional de EE. UU. CommScope ayuda a hacer que la transición de quitar y reemplazar componentes sea rápida, fácil y rentable.
    Descargar
  • Documento: Alimentación de energía resistente en la era de 5G

    ¿Cómo dimensionar los sistemas de suministro de potencia del emplazamiento de células para garantizar que las radios montadas en torre reciben suficiente voltaje durante el funcionamiento normal y los cortes de energía? La solución de fuente de alimentación dinámica PowerShift de CommScope brinda una alimentación de energía inherentemente resistente mientras reutiliza cables troncales existentes.
    Descargar
  • Documento: Reducir la disipación: pérdidas de energía de CC inducidas en emplazamientos de macro células

    Debido a que la demanda de energía de unidades de radio remotas (RRU) ha aumentado en la era de LTE y seguirá aumentando significativamente con la llegada de 5G, se vuelve más importante encontrar maneras de mejorar la eficiencia energética y minimizar la disipación de energía en emplazamientos de célula inalámbricos.
    Descargar
  • Documento: Una guía de planificación para optimizar la capacidad de las redes con ejemplos de campo prácticos

    Este documento explica cómo seleccionar y utilizar los componentes RF en sus emplazamientos para optimizar las capacidades de las redes celulares usando ejemplos de productos de la vida real.
    Descargar

Clasificar por:

Filtros

  • Brochure: CommScope solutions para el programa de quitar y reemplazar componentes de EE. UU.

    Los encargados de hacer el equipo de red son importantes en lo que respecta a la seguridad nacional de EE. UU. CommScope ayuda a hacer que la transición de quitar y reemplazar componentes sea rápida, fácil y rentable.
    Descargar
  • Documento: Alimentación de energía resistente en la era de 5G

    ¿Cómo dimensionar los sistemas de suministro de potencia del emplazamiento de células para garantizar que las radios montadas en torre reciben suficiente voltaje durante el funcionamiento normal y los cortes de energía? La solución de fuente de alimentación dinámica PowerShift de CommScope brinda una alimentación de energía inherentemente resistente mientras reutiliza cables troncales existentes.
    Descargar
  • Documento: Reducir la disipación: pérdidas de energía de CC inducidas en emplazamientos de macro células

    Debido a que la demanda de energía de unidades de radio remotas (RRU) ha aumentado en la era de LTE y seguirá aumentando significativamente con la llegada de 5G, se vuelve más importante encontrar maneras de mejorar la eficiencia energética y minimizar la disipación de energía en emplazamientos de célula inalámbricos.
    Descargar
  • Documento: Una guía de planificación para optimizar la capacidad de las redes con ejemplos de campo prácticos

    Este documento explica cómo seleccionar y utilizar los componentes RF en sus emplazamientos para optimizar las capacidades de las redes celulares usando ejemplos de productos de la vida real.
    Descargar