Warning Icon
This product was discontinued on: July 30, 2021

For other alternatives, please contact us for more information.

0 Replacement products available

RCT6-LTC-5A-RNAM

RCT6, RADIAX® Coaxial Radiating Cable with Bump, 70–960 MHz, tuned foil, 1-1/4 in, black non-halogenated, fire retardant polyolefin jacket

Specifications
Finish making your selections or clear them to view relevant specifications.

Product Classification

Product Type Radiating cable
Product Brand RADIAX®
Product Series RCT6

General Specifications

Polarization Vertical
Cable Type Radiating Mode (RCT) Series
Jacket Color Black
Tape Barrier Mica

Dimensions

Diameter Over Jacket 39.116 mm | 1.54 in
Inner Conductor OD 14.208 mm | 0.559 in
Outer Conductor OD 34.29 mm | 1.35 in
Nominal Size 1-1/4 in
Recommended Distance from the Wall 101.6 mm | 4 in
Recommended Hanger Spacing 1.3 m | 4.265 ft

Electrical Specifications

Attenuation Test Method IEC 61196-4
Attenuation Tolerance ±5%
Cable Impedance 50 ohm ±3 ohm
dc Resistance, Inner Conductor 1.74 ohms/km | 0.53 ohms/kft
dc Resistance, Outer Conductor 2.953 ohms/km | 0.9 ohms/kft
dc Test Voltage 8500 V
Insulation Resistance 100000 MOhms-km
Jacket Spark Test Voltage (rms) 10000 V
Operating Frequency Band 50 – 1000 MHz
Optimum Operating Frequency Band 70 – 960 MHz
Peak Power 180 kW
Stop Bands 520 – 600 MHz
Velocity 91 %
VSWR Installed, typical, 50–960 MHz 1.2999999523162842
VSWR on Reel, typical 1.4299999475479126

Attenuation

Frequency Attenuation (dB/100 m) Attenuation (dB/100 ft) Coupling Loss 50% Coupling Loss 95%
75.0 MHz 0.800 0.240 60 72
100.0 MHz 0.900 0.270 61 70
150.0 MHz 1.100 0.330 67 80
350.0 MHz 1.700 0.520 70 78
450.0 MHz 1.900 0.580 66 70
800.0 MHz 2.700 0.830 62 66
900.0 MHz 3.000 0.910 63 67

Material Specifications

Dielectric Material Foam PE
Jacket Material Non-halogenated, fire retardant polyolefin
Inner Conductor Material Corrugated copper tube
Outer Conductor Material Copper foil

Mechanical Specifications

Minimum Bend Radius, Single Bend 381 mm | 15 in
Tensile Strength 168 kg | 370.376 lb
Bending Moment 15.5 N-m | 137.187 in lb
Coupling Loss Test Method IEC 61196-4
Coupling Loss Tolerance ±5 dB
Flat Plate Crush Strength 1.4 kg/mm | 78.396 lb/in
Indication of Slot Alignment Yes–bumps face the wall

Environmental Specifications

Installation temperature -30 °C to +60 °C (-22 °F to +140 °F)
Operating Temperature -30 °C to +80 °C (-22 °F to +176 °F)
Storage Temperature -30 °C to +80 °C (-22 °F to +176 °F)
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Average Power, Inner Conductor Temperature 100 °C | 212 °F
Fire Retardancy Test Method IEC 60332-1-2 | IEC 60332-3C-24 | NFPA 130-2010
Smoke Index Test Method IEC 61034
Toxicity Index Test Method IEC 60754-1 | IEC 60754-2

Packaging and Weights

Cable weight 0.64 kg/m | 0.430 lb/ft

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system

Product Classification

Product Type Radiating cable
Product Brand RADIAX®
Product Series RCT6

General Specifications

Polarization Vertical
Cable Type Radiating Mode (RCT) Series
Jacket Color Black
Tape Barrier Mica

Dimensions

Diameter Over Jacket 39.116 mm | 1.54 in
Inner Conductor OD 14.208 mm | 0.559 in
Outer Conductor OD 34.29 mm | 1.35 in
Nominal Size 1-1/4 in
Recommended Distance from the Wall 101.6 mm | 4 in
Recommended Hanger Spacing 1.3 m | 4.265 ft

Electrical Specifications

Attenuation Test Method IEC 61196-4
Attenuation Tolerance ±5%
Cable Impedance 50 ohm ±3 ohm
dc Resistance, Inner Conductor 1.74 ohms/km | 0.53 ohms/kft
dc Resistance, Outer Conductor 2.953 ohms/km | 0.9 ohms/kft
dc Test Voltage 8500 V
Insulation Resistance 100000 MOhms-km
Jacket Spark Test Voltage (rms) 10000 V
Operating Frequency Band 50 – 1000 MHz
Optimum Operating Frequency Band 70 – 960 MHz
Peak Power 180 kW
Stop Bands 520 – 600 MHz
Velocity 91 %
VSWR Installed, typical, 50–960 MHz 1.2999999523162842
VSWR on Reel, typical 1.4299999475479126

Attenuation

Frequency Attenuation (dB/100 m) Attenuation (dB/100 ft) Coupling Loss 50% Coupling Loss 95%
75.0 MHz 0.800 0.240 60 72
100.0 MHz 0.900 0.270 61 70
150.0 MHz 1.100 0.330 67 80
350.0 MHz 1.700 0.520 70 78
450.0 MHz 1.900 0.580 66 70
800.0 MHz 2.700 0.830 62 66
900.0 MHz 3.000 0.910 63 67

Material Specifications

Dielectric Material Foam PE
Jacket Material Non-halogenated, fire retardant polyolefin
Inner Conductor Material Corrugated copper tube
Outer Conductor Material Copper foil

Mechanical Specifications

Minimum Bend Radius, Single Bend 381 mm | 15 in
Tensile Strength 168 kg | 370.376 lb
Bending Moment 15.5 N-m | 137.187 in lb
Coupling Loss Test Method IEC 61196-4
Coupling Loss Tolerance ±5 dB
Flat Plate Crush Strength 1.4 kg/mm | 78.396 lb/in
Indication of Slot Alignment Yes–bumps face the wall

Environmental Specifications

Installation temperature -30 °C to +60 °C (-22 °F to +140 °F)
Operating Temperature -30 °C to +80 °C (-22 °F to +176 °F)
Storage Temperature -30 °C to +80 °C (-22 °F to +176 °F)
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Average Power, Inner Conductor Temperature 100 °C | 212 °F
Fire Retardancy Test Method IEC 60332-1-2 | IEC 60332-3C-24 | NFPA 130-2010
Smoke Index Test Method IEC 61034
Toxicity Index Test Method IEC 60754-1 | IEC 60754-2

Packaging and Weights

Cable weight 0.64 kg/m | 0.430 lb/ft

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system

Product Specification

Product Specification