Warning Icon
This product was discontinued on: January 31, 2010

For other alternatives, please contact us for more information.

1 Replacement products available
  • CA-DMDM
    7-16 DIN Male to 7-16 DIN Male Adapter

TA-PDMDM

7-16 DIN Male to 7-16 DIN Male Adapter

Specifications
Finish making your selections or clear them to view relevant specifications.

Product Classification

Product Type Adapter

General Specifications

Body Style Straight
Inner Contact Plating Silver
Interface 7-16 DIN Male
Interface 2 7-16 DIN Male
Mounting Angle Straight
Outer Contact Plating Silver
Pressurizable No

Dimensions

Width 31.75 mm | 1.25 in
Length 42.44 mm | 1.671 in
Diameter 31.75 mm | 1.25 in

Outline Drawing

Click on image to enlarge.

Electrical Specifications

3rd Order IMD at Frequency -163 dBc @ 910 MHz
3rd Order IMD Test Method Two +43 dBm carriers
Average Power at Frequency 1,300.0 W @ 900 MHz
Connector Impedance 50 ohm
dc Test Voltage 4000 V
Inner Contact Resistance, maximum 0.4 mOhm
Insulation Resistance, minimum 10000 mOhm
Operating Frequency Band 0 – 3000 MHz
Outer Contact Resistance, maximum 1.5 mOhm
Peak Power, maximum 28.8 kW
RF Operating Voltage, maximum (vrms) 1200 V

Return Loss/VSWR

Frequency Band VSWR Return Loss (dB)
824–960 MHz 1.016 42.01
1710–1880 MHz 1.030 36.61
1850–1990 MHz 1.030 36.61
1910–2200 MHz 1.030 36.61
2200–2700 MHz 1.030 36.61

Mechanical Specifications

Coupling Nut Proof Torque 50 N-m | 442.537 in lb
Coupling Nut Proof Torque Method IEC 61169-4:9.3.6
Coupling Nut Retention Force 800 N | 179.847 lbf
Coupling Nut Retention Force Method IEC 61169-4:9.3.11
Insertion Force 200 N | 44.962 lbf
Insertion Force Method IEC 61169-4:15.2.4
Interface Durability 500 cycles
Interface Durability Method IEC 61169-4:9.5
Mechanical Shock Test Method IEC 60068-2-27

Environmental Specifications

Operating Temperature -55 °C to +85 °C (-67 °F to +185 °F)
Storage Temperature -65 °C to +125 °C (-85 °F to +257 °F)
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Average Power, Inner Conductor Temperature 100 °C | 212 °F
Climatic Sequence Test Method IEC 60068-1
Corrosion Test Method IEC 60068-2-11
Damp Heat Steady State Test Method IEC 60068-2-3
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6

Packaging and Weights

Weight, net 148 g | 0.326 lb

Product Classification

Product Type Adapter

General Specifications

Body Style Straight
Inner Contact Plating Silver
Interface 7-16 DIN Male
Interface 2 7-16 DIN Male
Mounting Angle Straight
Outer Contact Plating Silver
Pressurizable No

Dimensions

Width 31.75 mm | 1.25 in
Length 42.44 mm | 1.671 in
Diameter 31.75 mm | 1.25 in

Electrical Specifications

3rd Order IMD at Frequency -163 dBc @ 910 MHz
3rd Order IMD Test Method Two +43 dBm carriers
Average Power at Frequency 1,300.0 W @ 900 MHz
Connector Impedance 50 ohm
dc Test Voltage 4000 V
Inner Contact Resistance, maximum 0.4 mOhm
Insulation Resistance, minimum 10000 mOhm
Operating Frequency Band 0 – 3000 MHz
Outer Contact Resistance, maximum 1.5 mOhm
Peak Power, maximum 28.8 kW
RF Operating Voltage, maximum (vrms) 1200 V

Return Loss/VSWR

Frequency Band VSWR Return Loss (dB)
824–960 MHz 1.016 42.01
1710–1880 MHz 1.030 36.61
1850–1990 MHz 1.030 36.61
1910–2200 MHz 1.030 36.61
2200–2700 MHz 1.030 36.61

Mechanical Specifications

Coupling Nut Proof Torque 50 N-m | 442.537 in lb
Coupling Nut Proof Torque Method IEC 61169-4:9.3.6
Coupling Nut Retention Force 800 N | 179.847 lbf
Coupling Nut Retention Force Method IEC 61169-4:9.3.11
Insertion Force 200 N | 44.962 lbf
Insertion Force Method IEC 61169-4:15.2.4
Interface Durability 500 cycles
Interface Durability Method IEC 61169-4:9.5
Mechanical Shock Test Method IEC 60068-2-27

Environmental Specifications

Operating Temperature -55 °C to +85 °C (-67 °F to +185 °F)
Storage Temperature -65 °C to +125 °C (-85 °F to +257 °F)
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Average Power, Inner Conductor Temperature 100 °C | 212 °F
Climatic Sequence Test Method IEC 60068-1
Corrosion Test Method IEC 60068-2-11
Damp Heat Steady State Test Method IEC 60068-2-3
Thermal Shock Test Method IEC 60068-2-14
Vibration Test Method IEC 60068-2-6

Packaging and Weights

Weight, net 148 g | 0.326 lb
Click on image to enlarge.

Product Specification

Product Specification