RCT4-WBC-1X-RNA

RCT4, RADIAX® Coaxial Radiating Cable with Bump, 50–3800 MHz, foil, 1/2 in, black non-halogenated, fire retardant polyolefin jacket

Product Classification  
Brand   RADIAX®
Product Series   RCT4
Product Type   Radiating cable
   
Construction Materials  
Jacket Material   Non-halogenated, fire retardant polyolefin
Dielectric Material   Foam PE
Inner Conductor Material   Copper-clad aluminum wire
Jacket Color   Black
Outer Conductor Material   Copper foil
   
Dimensions  
Nominal Size   1/2 in
Diameter Over Jacket, maximum   16.256 mm   |   0.640 in
Inner Conductor OD   4.8260 mm   |   0.1900 in
Outer Conductor OD   12.954 mm   |   0.510 in
Cable Weight   0.13 lb/ft   |   0.19 kg/m
   
Electrical Specifications  
Operating Frequency Band   50 – 3800 MHz
Polarization   Vertical
Velocity   88 %
VSWR Installed, typical, 1700–2700 MHz   1.38
VSWR Installed, typical, 50–960 MHz   1.30
VSWR on Reel, typical   1.43
Cable Impedance   50 ohm ±3 ohm
dc Resistance, Inner Conductor   0.450 ohms/kft   |   1.480 ohms/km
dc Resistance, Outer Conductor   1.617 ohms/kft   |   5.305 ohms/km
dc Test Voltage   4000 V
Insulation Resistance   100000 Mohms•km
Jacket Spark Test Voltage (rms)   8000 V
Peak Power   40.0 kW
   
Environmental Specifications  
Installation Temperature   -30 °C to +60 °C (-22 °F to +140 °F)
Operating Temperature   -30 °C to +80 °C (-22 °F to +176 °F)
Storage Temperature   -30 °C to +80 °C (-22 °F to +176 °F)
   
General Specifications  
Cable Type   Coupled Mode Series
   
Mechanical Specifications  
Bending Moment   3.7 N-m   |   2.7 ft lb
Flat Plate Crush Strength   40.0 lb/in   |   0.7 kg/mm
Indication of Slot Alignment   Yes–bumps face the wall
Minimum Bend Radius, Single Bend   127.00 mm   |   5.00 in
Recommended Distance from the Wall   50.8 mm   |   2.0 in
Recommended Hanger Spacing   1.0 m   |   3.3 ft
Tensile Strength   45 kg   |   100 lb
Fire Retardancy Test Method   IEC 60332-1   |   IEC 60332-3C-24
Smoke Index Test Method   IEC 61034
Toxicity Index Test Method   IEC 60754-1   |   IEC 60754-2
   
Standard Conditions  
Attenuation Test Method   IEC 61196-4
Attenuation Tolerance   ±5%
Attenuation, Ambient Temperature   20 °C   |   68 °F
Average Power, Ambient Temperature   40 °C   |   104 °F
Average Power, Inner Conductor Temperature   100 °C   |   212 °F
Coupling Loss Test Method   IEC 61196-4
Coupling Loss Tolerance   ±10 dB
Electrical Performance
FrequencyAttenuation (dB/100 m)Attenuation (dB/100 ft)Coupling Loss 50%Coupling Loss 95%
75 MHz1.800.545967
100 MHz2.100.655263
150 MHz2.600.796171
350 MHz3.901.197283
450 MHz4.401.347484
700 MHz6.401.957383
800 MHz6.902.107384
900 MHz7.402.307385
960 MHz7.702.407385
1700 MHz10.703.307081
1800 MHz11.203.406980
1900 MHz11.503.507182
2000 MHz11.603.606981
2100 MHz12.303.707284
2200 MHz12.503.807082
2300 MHz13.304.106475
2400 MHz13.804.206677
2500 MHz14.304.406677
2600 MHz14.704.506575
2700 MHz15.404.706375
2800 MHz16.004.906070
3300 MHz18.205.505665
3400 MHz18.605.705665
3500 MHz19.105.805665
3600 MHz20.806.335865
3700 MHz21.406.526065
3800 MHz22.206.766167

Regulatory Compliance/Certifications
AgencyClassification
RoHS 2011/65/EUCompliant
ISO 9001:2015Designed, manufactured and/or distributed under this quality management system

Logo Logo
Add Cancel
Powered By OneLink