Warning Icon

For other alternatives, please contact us for more information.

0 Alternative products available

5209002 | P3® 875 CA

  • Available in:
  • North America

75 Ohm P3® Trunk and Distribution Cable, unjacketed

Find a Partner
Specifications
Finish making your selections or clear them to view relevant specifications.
BABA-compliant
Build America Buy America (BABA)*

Rely on CommScope for Broadband Equity Access and Development (BEAD) Program and other government funded projects

Broadband for Everyone Program

Features and Benefits
  • *Product complies with the Build America, Buy America Act (BABAA) requirements of the Infrastructure Investment and Jobs Act of 2021 (Pub. L. 117- 58, §§ 70901-70953), or is the subject of a waiver approved by the Secretary of Commerce or designee. Compliance requirements and waiver applicability vary based on government funding program. Check the laws and regulations for your specific program.

Product Classification

Regional Availability North America
Product Type Coaxial hardline cable
Product Brand P3®
Government Requirements Build America Buy America (BABA) compliant*
Warranty One year

General Specifications

Cable Type 875 Series
Construction Type Swaged
Jacket Color Unjacketed
Location of Manufacturing Catawba, North Carolina
Short Description P3 875 CA

Dimensions

Cable Length 762 m | 2500 ft
Diameter Over Center Conductor, nominal 4.928 mm | 0.194 in
Diameter Over Dielectric, nominal 20.244 mm | 0.797 in
Diameter Over Outer Conductor, nominal 22.225 mm | 0.875 in
Outer Conductor Thickness, nominal 0.991 mm | 0.039 in

Electrical Specifications

Capacitance 50.197 pF/m | 15.3 pF/ft
Capacitance Tolerance ±1.0 pF/ft
Characteristic Impedance 75 ohm
Characteristic Impedance Tolerance ±2 ohm
dc Resistance Note Nominal values based on a standard condition of 20 °C (68 °F)
dc Resistance, Inner Conductor, nominal 1.378 ohms/km | 0.42 ohms/kft
dc Resistance, Loop, nominal 1.804 ohms/km | 0.55 ohms/kft
dc Resistance, Outer Conductor, nominal 0.427 ohms/km | 0.13 ohms/kft
Nominal Velocity of Propagation (NVP) 87 %
Operating Frequency Band 5–3000 MHz
Structural Return Loss 24 dB @ 1003–1218 MHz | 24 dB @ 1219–1794 MHz | 30 dB @ 5–1002 MHz
Structural Return Loss, Grade N ≥24 dB @ 1003–1218 MHz | ≥24 dB @ 1219–1794 MHz | ≥30 dB @ 5–1002 MHz

Attenuation

Frequency Attenuation (dB/100 m) Attenuation (dB/100 ft)
5.0 MHz 0.300 0.090
55.0 MHz 1.080 0.330
85.0 MHz 1.310 0.400
204.0 MHz 2.070 0.630
211.0 MHz 2.170 0.660
250.0 MHz 2.360 0.720
300.0 MHz 2.560 0.780
350.0 MHz 2.760 0.840
400.0 MHz 2.990 0.910
450.0 MHz 3.180 0.970
500.0 MHz 3.380 1.030
550.0 MHz 3.540 1.080
600.0 MHz 3.740 1.140
750.0 MHz 4.230 1.290
865.0 MHz 4.630 1.410
1002.0 MHz 5.020 1.530
1218.0 MHz 5.570 1.700
1500.0 MHz 6.390 1.950
1794.0 MHz 7.130 2.170
1800.0 MHz 7.140 2.180
2000.0 MHz 7.620 2.320
2200.0 MHz 8.090 2.460
2500.0 MHz 8.760 2.670
2700.0 MHz 9.190 2.800
3000.0 MHz 9.830 3.000

Material Specifications

Center Conductor Material Copper-clad aluminum
Dielectric Material Foam PE
Jacket Material Unjacketed
Outer Conductor Material Aluminum

Mechanical Specifications

Minimum Bend Radius, standard 254 mm | 10 in
Pulling Tension, maximum 396.893 kg | 875 lb

Environmental Specifications

Environmental Space Aerial

Packaging and Weights

Packaging Type Reel
Weight, gross 446.449 kg/km | 300 lb/kft

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system

Product Classification

Regional Availability North America
Product Type Coaxial hardline cable
Product Brand P3®
Government Requirements Build America Buy America (BABA) compliant*
Warranty One year

General Specifications

Cable Type 875 Series
Construction Type Swaged
Jacket Color Unjacketed
Location of Manufacturing Catawba, North Carolina
Short Description P3 875 CA

Dimensions

Cable Length 762 m | 2500 ft
Diameter Over Center Conductor, nominal 4.928 mm | 0.194 in
Diameter Over Dielectric, nominal 20.244 mm | 0.797 in
Diameter Over Outer Conductor, nominal 22.225 mm | 0.875 in
Outer Conductor Thickness, nominal 0.991 mm | 0.039 in

Electrical Specifications

Capacitance 50.197 pF/m | 15.3 pF/ft
Capacitance Tolerance ±1.0 pF/ft
Characteristic Impedance 75 ohm
Characteristic Impedance Tolerance ±2 ohm
dc Resistance Note Nominal values based on a standard condition of 20 °C (68 °F)
dc Resistance, Inner Conductor, nominal 1.378 ohms/km | 0.42 ohms/kft
dc Resistance, Loop, nominal 1.804 ohms/km | 0.55 ohms/kft
dc Resistance, Outer Conductor, nominal 0.427 ohms/km | 0.13 ohms/kft
Nominal Velocity of Propagation (NVP) 87 %
Operating Frequency Band 5–3000 MHz
Structural Return Loss 24 dB @ 1003–1218 MHz | 24 dB @ 1219–1794 MHz | 30 dB @ 5–1002 MHz
Structural Return Loss, Grade N ≥24 dB @ 1003–1218 MHz | ≥24 dB @ 1219–1794 MHz | ≥30 dB @ 5–1002 MHz

Attenuation

Frequency Attenuation (dB/100 m) Attenuation (dB/100 ft)
5.0 MHz 0.300 0.090
55.0 MHz 1.080 0.330
85.0 MHz 1.310 0.400
204.0 MHz 2.070 0.630
211.0 MHz 2.170 0.660
250.0 MHz 2.360 0.720
300.0 MHz 2.560 0.780
350.0 MHz 2.760 0.840
400.0 MHz 2.990 0.910
450.0 MHz 3.180 0.970
500.0 MHz 3.380 1.030
550.0 MHz 3.540 1.080
600.0 MHz 3.740 1.140
750.0 MHz 4.230 1.290
865.0 MHz 4.630 1.410
1002.0 MHz 5.020 1.530
1218.0 MHz 5.570 1.700
1500.0 MHz 6.390 1.950
1794.0 MHz 7.130 2.170
1800.0 MHz 7.140 2.180
2000.0 MHz 7.620 2.320
2200.0 MHz 8.090 2.460
2500.0 MHz 8.760 2.670
2700.0 MHz 9.190 2.800
3000.0 MHz 9.830 3.000

Material Specifications

Center Conductor Material Copper-clad aluminum
Dielectric Material Foam PE
Jacket Material Unjacketed
Outer Conductor Material Aluminum

Mechanical Specifications

Minimum Bend Radius, standard 254 mm | 10 in
Pulling Tension, maximum 396.893 kg | 875 lb

Environmental Specifications

Environmental Space Aerial

Packaging and Weights

Packaging Type Reel
Weight, gross 446.449 kg/km | 300 lb/kft

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system