Warning Icon

For other alternatives, please contact us for more information.

0 Alternative products available

884024508/10 | CS44Z1 WHT C6A 4/23 F/UTP RL 305M

Base Product: CS44Z

  • Available in:
  • Asia
  • Australia/New Zealand
  • China
  • India
  • Latin America

CS44Z1 Category 6A, F/UTP Cable, low smoke zero halogen, white jacket, 4 pair count, 1000 ft (305 m) length reel

Find a Partner
Specifications
Finish making your selections or clear them to view relevant specifications.

Product Classification

Regional Availability Asia | Australia/New Zealand | China | India | Latin America
Portfolio NETCONNECT®
Product Type Twisted pair cable

General Specifications

Product Number CS44Z1
ANSI/TIA Category 6A
Cable Component Type Horizontal
Cable Type F/UTP (shielded)
Conductor Type, singles Solid
Conductors, quantity 8
Drain Wire Type Solid
Jacket Color White
Note All electrical transmission tests include swept frequency measurements
Pairs, quantity 4
Separator Type Isolator
Transmission Standards ANSI/TIA-568.2-D | ISO/IEC 11801 Class EA

Dimensions

Cable Length 304.8 m | 1000 ft
Diameter Over Insulated Conductor 1.140 mm | 0.0449 in
Diameter Over Jacket, nominal 7.188 mm | 0.283 in
Conductor Gauge, singles 23 AWG
Drain Wire Gauge 26 AWG

Cross Section Drawing

Click on image to enlarge.

Electrical Specifications

Characteristic Impedance 100 ohm
Characteristic Impedance Tolerance ±15 ohm
dc Resistance, maximum 7.8 ohms/100 m | 2.377 ohms/100 ft
Delay Skew, maximum 45 ns
Dielectric Strength, minimum 1500 Vac | 2500 Vdc
Mutual Capacitance at Frequency 5.6 nF/100 m @ 1 kHz
Nominal Velocity of Propagation (NVP) 69 %
Operating Frequency, maximum 500 MHz
Operating Voltage, maximum 80 V
Propagation Delay, maximum 536 ns/100m @500MHz
Remote Powering Fully complies with the recommendations set forth by IEEE 802.3bt (Type 4) for the safe delivery of power over LAN cable when installed according to ISO/IEC 14763-2, CENELEC EN 50174-1, CENELEC EN 50174-2 or TIA TSB-184-A
Segregation Class c

Electrical Cable Performance

CS
CommScope
Std
Refers to the standard value listed under Transmission Standards in the Electrical Specifications above
Typ
Typical
IL
Insertion Loss (dB/100m)
NEXT
Near End Crosstalk (dB/100m)
ACR
Attenuation to Crosstalk Ratio (dB/100m))
PSNEXT
Power Sum Near End Crosstalk (db/100m)
PSACR
Power Sum Attenuation to Crosstalk Ratio (dB/100m)
ACRF
Attenuation to Crosstalk Ratio - Far End (dB/100m)
PSACRF
Insertion Loss (dB/100m)
RL
Return Loss (dB)
Frequency IL, STD NEXT, STD ACR, STD PSNEXT, STD PSACR, STD ACRF, STD PSACRF, STD RL, STD
1.00 MHz 2.1 75.3 73.2 72.3 70.2 68.0 65.0 20.0
4.00 MHz 3.8 66.3 62.5 63.3 59.5 56.0 53.0 23.0
8.00 MHz 5.3 61.8 56.4 58.8 53.4 49.9 46.9 24.5
10.00 MHz 5.9 60.3 54.4 57.3 51.4 48.0 45.0 25.0
16.00 MHz 7.5 57.2 49.8 54.2 46.8 43.9 40.9 25.0
20.00 MHz 8.4 55.8 47.4 52.8 44.4 42.0 39.0 25.0
25.00 MHz 9.4 54.3 45.0 51.3 42.0 40.0 37.0 24.3
31.25 MHz 10.5 52.9 42.4 49.9 39.4 38.1 35.1 23.6
62.50 MHz 15.0 48.4 33.4 45.4 30.4 32.1 29.1 21.5
100.00 MHz 19.1 45.3 26.2 42.3 23.2 28.0 25.0 20.1
155.00 MHz 24.1 42.4 18.4 39.4 15.4 24.2 21.2 18.8
200.00 MHz 27.6 40.8 13.2 37.8 10.2 22.0 19.0 18.0
250.00 MHz 31.1 39.3 8.3 36.3 5.3 20.0 17.0 17.3
300.00 MHz 34.3 38.1 3.9 35.1 0.9 18.5 15.5 16.8
350.00 MHz 37.2 37.1 -0.1 34.1 -3.1 17.1 14.1 16.3
400.00 MHz 40.1 36.3 -3.8 33.3 -6.8 16.0 13.0 15.9
500.00 MHz 45.3 34.8 -10.4 31.8 -13.4 14.0 11.0 15.2

Material Specifications

Conductor Material Bare copper
Insulation Material Polyolefin
Jacket Material Low Smoke Zero Halogen (LSZH)
Shield (Tape) Material Aluminum/Polyester

Mechanical Specifications

Minimum Bend Radius Note 8 times the outer cable diameter
Pulling Tension, maximum 11.34 kg | 25 lb

Environmental Specifications

Installation temperature 0 °C to +60 °C (+32 °F to +140 °F)
Operating Temperature -20 °C to +75 °C (-4 °F to +167 °F)
Acid Gas Test Method IEC 60754-2
EN50575 CPR Cable EuroClass Fire Performance No Rating
Environmental Space Low Smoke Zero Halogen (LSZH)
Temperature Rating, UL 75 °C | 167.000 °F
Flame Test Method IEC 60332-1
Smoke Test Method IEC 61034-2

Packaging and Weights

Packaging Type Reel

Regulatory Compliance/Certifications

Agency Classification
ROHS Compliant
CHINA-ROHS Below maximum concentration value
REACH-SVHC Compliant as per SVHC revision on www.commscope.com/ProductCompliance
UK-ROHS Compliant

Product Classification

Regional Availability Asia | Australia/New Zealand | China | India | Latin America
Portfolio NETCONNECT®
Product Type Twisted pair cable

General Specifications

Product Number CS44Z1
ANSI/TIA Category 6A
Cable Component Type Horizontal
Cable Type F/UTP (shielded)
Conductor Type, singles Solid
Conductors, quantity 8
Drain Wire Type Solid
Jacket Color White
Note All electrical transmission tests include swept frequency measurements
Pairs, quantity 4
Separator Type Isolator
Transmission Standards ANSI/TIA-568.2-D | ISO/IEC 11801 Class EA

Dimensions

Cable Length 304.8 m | 1000 ft
Diameter Over Insulated Conductor 1.140 mm | 0.0449 in
Diameter Over Jacket, nominal 7.188 mm | 0.283 in
Conductor Gauge, singles 23 AWG
Drain Wire Gauge 26 AWG

Electrical Specifications

Characteristic Impedance 100 ohm
Characteristic Impedance Tolerance ±15 ohm
dc Resistance, maximum 7.8 ohms/100 m | 2.377 ohms/100 ft
Delay Skew, maximum 45 ns
Dielectric Strength, minimum 1500 Vac | 2500 Vdc
Mutual Capacitance at Frequency 5.6 nF/100 m @ 1 kHz
Nominal Velocity of Propagation (NVP) 69 %
Operating Frequency, maximum 500 MHz
Operating Voltage, maximum 80 V
Propagation Delay, maximum 536 ns/100m @500MHz
Remote Powering Fully complies with the recommendations set forth by IEEE 802.3bt (Type 4) for the safe delivery of power over LAN cable when installed according to ISO/IEC 14763-2, CENELEC EN 50174-1, CENELEC EN 50174-2 or TIA TSB-184-A
Segregation Class c

Electrical Cable Performance

CS
CommScope
Std
Refers to the standard value listed under Transmission Standards in the Electrical Specifications above
Typ
Typical
IL
Insertion Loss (dB/100m)
NEXT
Near End Crosstalk (dB/100m)
ACR
Attenuation to Crosstalk Ratio (dB/100m))
PSNEXT
Power Sum Near End Crosstalk (db/100m)
PSACR
Power Sum Attenuation to Crosstalk Ratio (dB/100m)
ACRF
Attenuation to Crosstalk Ratio - Far End (dB/100m)
PSACRF
Insertion Loss (dB/100m)
RL
Return Loss (dB)
Frequency IL, STD NEXT, STD ACR, STD PSNEXT, STD PSACR, STD ACRF, STD PSACRF, STD RL, STD
1.00 MHz 2.1 75.3 73.2 72.3 70.2 68.0 65.0 20.0
4.00 MHz 3.8 66.3 62.5 63.3 59.5 56.0 53.0 23.0
8.00 MHz 5.3 61.8 56.4 58.8 53.4 49.9 46.9 24.5
10.00 MHz 5.9 60.3 54.4 57.3 51.4 48.0 45.0 25.0
16.00 MHz 7.5 57.2 49.8 54.2 46.8 43.9 40.9 25.0
20.00 MHz 8.4 55.8 47.4 52.8 44.4 42.0 39.0 25.0
25.00 MHz 9.4 54.3 45.0 51.3 42.0 40.0 37.0 24.3
31.25 MHz 10.5 52.9 42.4 49.9 39.4 38.1 35.1 23.6
62.50 MHz 15.0 48.4 33.4 45.4 30.4 32.1 29.1 21.5
100.00 MHz 19.1 45.3 26.2 42.3 23.2 28.0 25.0 20.1
155.00 MHz 24.1 42.4 18.4 39.4 15.4 24.2 21.2 18.8
200.00 MHz 27.6 40.8 13.2 37.8 10.2 22.0 19.0 18.0
250.00 MHz 31.1 39.3 8.3 36.3 5.3 20.0 17.0 17.3
300.00 MHz 34.3 38.1 3.9 35.1 0.9 18.5 15.5 16.8
350.00 MHz 37.2 37.1 -0.1 34.1 -3.1 17.1 14.1 16.3
400.00 MHz 40.1 36.3 -3.8 33.3 -6.8 16.0 13.0 15.9
500.00 MHz 45.3 34.8 -10.4 31.8 -13.4 14.0 11.0 15.2

Material Specifications

Conductor Material Bare copper
Insulation Material Polyolefin
Jacket Material Low Smoke Zero Halogen (LSZH)
Shield (Tape) Material Aluminum/Polyester

Mechanical Specifications

Minimum Bend Radius Note 8 times the outer cable diameter
Pulling Tension, maximum 11.34 kg | 25 lb

Environmental Specifications

Installation temperature 0 °C to +60 °C (+32 °F to +140 °F)
Operating Temperature -20 °C to +75 °C (-4 °F to +167 °F)
Acid Gas Test Method IEC 60754-2
EN50575 CPR Cable EuroClass Fire Performance No Rating
Environmental Space Low Smoke Zero Halogen (LSZH)
Temperature Rating, UL 75 °C | 167.000 °F
Flame Test Method IEC 60332-1
Smoke Test Method IEC 61034-2

Packaging and Weights

Packaging Type Reel
Click on image to enlarge.

Regulatory Compliance/Certifications

Agency Classification
ROHS Compliant
CHINA-ROHS Below maximum concentration value
REACH-SVHC Compliant as per SVHC revision on www.commscope.com/ProductCompliance
UK-ROHS Compliant

3rd Party Certification - Component

Building Information Modeling (BIM) Objects

Product Specification

Product Sustainability

3rd Party Certification - Component

Building Information Modeling (BIM) Objects

Product Specification

Product Sustainability

Recommended for You