Warning Icon

For other alternatives, please contact us for more information.

0 Replacement products available

AVA6-50

AVA6-50, HELIAX® Andrew Virtual Air™ Coaxial Cable, corrugated copper, 1-1/4 in, black PE jacket (Halogen free jacketing non-fire-retardant)
Specifications
Finish making your selections or clear them to view relevant specifications.
How to Buy
Specifications

Attenuation

Frequency Attenuation (dB/100 m) Attenuation (dB/100 ft) Average Power (kW)
1.0 MHz 0.079 0.024 82.63
1.5 MHz 0.097 0.030 67.41
2.0 MHz 0.113 0.034 58.33
10.0 MHz 0.253 0.077 25.89
20.0 MHz 0.360 0.110 18.21
30.0 MHz 0.443 0.135 14.80
50.0 MHz 0.576 0.176 11.39
85.0 MHz 0.758 0.231 8.66
88.0 MHz 0.772 0.235 8.51
100.0 MHz 0.825 0.251 7.96
108.0 MHz 0.858 0.262 7.65
150.0 MHz 1.019 0.311 6.44
174.0 MHz 1.102 0.336 5.96
200.0 MHz 1.186 0.361 5.53
204.0 MHz 1.198 0.365 5.48
300.0 MHz 1.471 0.448 4.46
400.0 MHz 1.717 0.523 3.82
450.0 MHz 1.829 0.558 3.59
460.0 MHz 1.851 0.564 3.54
500.0 MHz 1.937 0.590 3.39
512.0 MHz 1.962 0.598 3.34
600.0 MHz 2.140 0.652 3.07
700.0 MHz 2.329 0.710 2.82
800.0 MHz 2.507 0.764 2.62
824.0 MHz 2.548 0.777 2.58
894.0 MHz 2.666 0.813 2.46
960.0 MHz 2.774 0.846 2.37
1000.0 MHz 2.838 0.865 2.31
1218.0 MHz 3.171 0.967 2.07
1250.0 MHz 3.218 0.981 2.04
1500.0 MHz 3.569 1.088 1.84
1700.0 MHz 3.835 1.169 1.71
1794.0 MHz 3.955 1.206 1.66
1800.0 MHz 3.963 1.208 1.66
2000.0 MHz 4.212 1.284 1.56
2100.0 MHz 4.333 1.321 1.51
2200.0 MHz 4.452 1.357 1.47
2300.0 MHz 4.569 1.393 1.44
2500.0 MHz 4.798 1.462 1.37
2700.0 MHz 5.021 1.530 1.31
3000.0 MHz 5.345 1.629 1.23
3400.0 MHz 5.760 1.755 1.14
3600.0 MHz 5.961 1.817 1.10
3700.0 MHz 6.060 1.847 1.08

Return Loss/VSWR

Frequency Band VSWR Return Loss (dB)
680–800 MHz 1.13 24.30
806–960 MHz 1.13 24.30
1700–2170 MHz 1.13 24.30

Product Classification

Product Type Coaxial wireless cable
Product Brand HELIAX®
Product Series AVA6-50
Ordering Note CommScope® standard product in the United States and Canada | CommScope® standard product in Asia Pacific

General Specifications

Flexibility Standard
Jacket Color Black

Dimensions

Diameter Over Dielectric 34.036 mm | 1.34 in
Diameter Over Jacket 39.624 mm | 1.56 in
Inner Conductor OD 14.0208 mm | 0.552 in
Outer Conductor OD 36.068 mm | 1.42 in
Nominal Size 1-1/4 in

Electrical Specifications

Attenuation, Ambient Temperature 68 °F | 20 °C
Cable Impedance 50 ohm ±1 ohm
Capacitance 72 pF/m | 21.946 pF/ft
dc Resistance, Inner Conductor 1.74 ohms/km | 0.53 ohms/kft
dc Resistance, Outer Conductor 0.75 ohms/km | 0.229 ohms/kft
dc Test Voltage 8500 V
Inductance 0.187 µH/m | 0.057 µH/ft
Insulation Resistance 100000 MOhms-km
Jacket Spark Test Voltage (rms) 10000 V
Operating Frequency Band 1 – 3700 MHz
Peak Power 180 kW
Velocity 92 %

Material Specifications

Dielectric Material Foam PE
Jacket Material PE
Inner Conductor Material Corrugated copper tube
Outer Conductor Material Corrugated copper

Mechanical Specifications

Minimum Bend Radius, multiple Bends 8 in | 203.2 mm
Minimum Bend Radius, Single Bend 6 in | 152.4 mm
Number of Bends, minimum 15
Number of Bends, typical 40
Tensile Strength 154 kg | 339.511 lb
Bending Moment 29.8 N-m | 263.752 in lb
Flat Plate Crush Strength 1.3 kg/mm | 72.797 lb/in

Environmental Specifications

Installation temperature -40 °C to +60 °C (-40 °F to +140 °F)
Operating Temperature -55 °C to +85 °C (-67 °F to +185 °F)
Storage Temperature -70 °C to +85 °C (-94 °F to +185 °F)
Average Power, Ambient Temperature 104 °F | 40 °C
Average Power, Inner Conductor Temperature 212 °F | 100 °C
EN50575 CPR Cable EuroClass Fire Performance Fca

Packaging and Weights

Cable weight 0.68 kg/m | 4.918 lb/ft

Regulatory Compliance/Certifications

Agency Classification
CENELEC CENELECEN 50575 compliant, Declaration of Performance (DoP) available
ISO 9001:2015 ISO 9001:2015Designed, manufactured and/or distributed under this quality management system
ROHS ROHSCompliant
CHINA-ROHS CHINA-ROHSBelow maximum concentration value
REACH-SVHC REACH-SVHCCompliant as per SVHC revision on www.commscope.com/ProductCompliance

Attenuation

Frequency Attenuation (dB/100 m) Attenuation (dB/100 ft) Average Power (kW)
1.0 MHz 0.079 0.024 82.63
1.5 MHz 0.097 0.030 67.41
2.0 MHz 0.113 0.034 58.33
10.0 MHz 0.253 0.077 25.89
20.0 MHz 0.360 0.110 18.21
30.0 MHz 0.443 0.135 14.80
50.0 MHz 0.576 0.176 11.39
85.0 MHz 0.758 0.231 8.66
88.0 MHz 0.772 0.235 8.51
100.0 MHz 0.825 0.251 7.96
108.0 MHz 0.858 0.262 7.65
150.0 MHz 1.019 0.311 6.44
174.0 MHz 1.102 0.336 5.96
200.0 MHz 1.186 0.361 5.53
204.0 MHz 1.198 0.365 5.48
300.0 MHz 1.471 0.448 4.46
400.0 MHz 1.717 0.523 3.82
450.0 MHz 1.829 0.558 3.59
460.0 MHz 1.851 0.564 3.54
500.0 MHz 1.937 0.590 3.39
512.0 MHz 1.962 0.598 3.34
600.0 MHz 2.140 0.652 3.07
700.0 MHz 2.329 0.710 2.82
800.0 MHz 2.507 0.764 2.62
824.0 MHz 2.548 0.777 2.58
894.0 MHz 2.666 0.813 2.46
960.0 MHz 2.774 0.846 2.37
1000.0 MHz 2.838 0.865 2.31
1218.0 MHz 3.171 0.967 2.07
1250.0 MHz 3.218 0.981 2.04
1500.0 MHz 3.569 1.088 1.84
1700.0 MHz 3.835 1.169 1.71
1794.0 MHz 3.955 1.206 1.66
1800.0 MHz 3.963 1.208 1.66
2000.0 MHz 4.212 1.284 1.56
2100.0 MHz 4.333 1.321 1.51
2200.0 MHz 4.452 1.357 1.47
2300.0 MHz 4.569 1.393 1.44
2500.0 MHz 4.798 1.462 1.37
2700.0 MHz 5.021 1.530 1.31
3000.0 MHz 5.345 1.629 1.23
3400.0 MHz 5.760 1.755 1.14
3600.0 MHz 5.961 1.817 1.10
3700.0 MHz 6.060 1.847 1.08

Return Loss/VSWR

Frequency Band VSWR Return Loss (dB)
680–800 MHz 1.13 24.30
806–960 MHz 1.13 24.30
1700–2170 MHz 1.13 24.30

Product Classification

Product Type Coaxial wireless cable
Product Brand HELIAX®
Product Series AVA6-50
Ordering Note CommScope® standard product in the United States and Canada | CommScope® standard product in Asia Pacific

General Specifications

Flexibility Standard
Jacket Color Black

Dimensions

Diameter Over Dielectric 34.036 mm | 1.34 in
Diameter Over Jacket 39.624 mm | 1.56 in
Inner Conductor OD 14.0208 mm | 0.552 in
Outer Conductor OD 36.068 mm | 1.42 in
Nominal Size 1-1/4 in

Electrical Specifications

Attenuation, Ambient Temperature 68 °F | 20 °C
Cable Impedance 50 ohm ±1 ohm
Capacitance 72 pF/m | 21.946 pF/ft
dc Resistance, Inner Conductor 1.74 ohms/km | 0.53 ohms/kft
dc Resistance, Outer Conductor 0.75 ohms/km | 0.229 ohms/kft
dc Test Voltage 8500 V
Inductance 0.187 µH/m | 0.057 µH/ft
Insulation Resistance 100000 MOhms-km
Jacket Spark Test Voltage (rms) 10000 V
Operating Frequency Band 1 – 3700 MHz
Peak Power 180 kW
Velocity 92 %

Material Specifications

Dielectric Material Foam PE
Jacket Material PE
Inner Conductor Material Corrugated copper tube
Outer Conductor Material Corrugated copper

Mechanical Specifications

Minimum Bend Radius, multiple Bends 8 in | 203.2 mm
Minimum Bend Radius, Single Bend 6 in | 152.4 mm
Number of Bends, minimum 15
Number of Bends, typical 40
Tensile Strength 154 kg | 339.511 lb
Bending Moment 29.8 N-m | 263.752 in lb
Flat Plate Crush Strength 1.3 kg/mm | 72.797 lb/in

Environmental Specifications

Installation temperature -40 °C to +60 °C (-40 °F to +140 °F)
Operating Temperature -55 °C to +85 °C (-67 °F to +185 °F)
Storage Temperature -70 °C to +85 °C (-94 °F to +185 °F)
Average Power, Ambient Temperature 104 °F | 40 °C
Average Power, Inner Conductor Temperature 212 °F | 100 °C
EN50575 CPR Cable EuroClass Fire Performance Fca

Packaging and Weights

Cable weight 0.68 kg/m | 4.918 lb/ft

Regulatory Compliance/Certifications

Agency Classification
CENELEC CENELECEN 50575 compliant, Declaration of Performance (DoP) available
ISO 9001:2015 ISO 9001:2015Designed, manufactured and/or distributed under this quality management system
ROHS ROHSCompliant
CHINA-ROHS CHINA-ROHSBelow maximum concentration value
REACH-SVHC REACH-SVHCCompliant as per SVHC revision on www.commscope.com/ProductCompliance
Documentation & Downloads

Declaration of Performance

Environment Health and Safety

Product Selection Guide

Product Specification

Warranty

Other Ways to Browse

Browse by Category

Browse by Application

Browse by Category

Browse by Application